Efficiency Test of IOT transmitter

Document #:
Project X-doc-927-v2
Document type:
technical note
Submitted by:
Ralph J. Pasquinelli
Updated by:
Ralph J. Pasquinelli
Document Created:
12 Sep 2011, 13:50
Contents Revised:
12 Sep 2011, 14:03
Metadata Revised:
12 Sep 2011, 14:03
Viewable by:
  • Public document
Modifiable by:

Quick Links:
Latest Version

Other Versions:
Project X-doc-927-v1
12 Sep 2011, 13:50
Abstract:
Attached are the test results from an efficiency test on the V2 E2V 30 KW IOT and transmitter plus Ferrite circulator. 480 VAC was monitored with a Fluke power energy analyzer directly attached to the mains input on the transmitter. AC power measured does not include power for the solid-state driver amplifiers, but does include fans, filaments, bias supplies, ion pump, controls, etc that are part of the main transmitter cabinet. RF power was measured with Agilent power meters. Calibrations of all couplers were done to an accuracy of 0.1 dB and these values were entered as offsets to the meters. An Agilent network analyzer was used to tune up the input and output cavities and coupling loops. Before the data was taken, an efficiency exceeding 50% AC to RF was tuned. Figure 1 shows a photo of the transmitter and circulator. At 30 KW, 6-1/8 inch coax is required. Initially loads are attached to both ports 2 and 3 of the circulator. A short circuit was then installed on port 2 of the circulator to reflect power to the load on port 3.
Files in Document:
Keywords:
IOT efficiency
DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ]

--------
Security, Privacy, Legal
Fermilab Policy on Computing
Fermi National Accelerator Laboratory

For assistance contact HelpDesk



DocDB Version 8.8.9, contact Document Database Administrators